A hotel exhausts every bathroom around the clock, and the make-up air that replaces it enters through the corridor. Viking OA delivers that air neutral and dry, so terminal units carry sensible load only and the corridor stays positively pressurized, every hour of the year.
The challenge

The challenge in this building type

The latent load in lodging is not a peak. It is a duty cycle. Continuous bathroom exhaust means continuous make-up air, and if that air arrives at outdoor dewpoint the corridor becomes the wettest space in the building and the guestroom PTAC is asked to remove moisture it was never selected for.

Continuous exhaust, continuous make-up

Bathroom exhaust runs 24/7 at code rates. Every cubic foot leaving must be replaced, and the replacement air carries the outdoor dewpoint unless something removes it first.

Terminal units cannot do latent

PTACs, VTACs and fan coils are selected for sensible load and cycle on temperature. Ask them to dehumidify corridor air and they short-cycle, overcool and lose.

Corridor pressure through door cycles

Elevators, stairs and entrances cycle all day. Positive corridor pressure has to be held by fan reset against the exhaust riser, not assumed.

Moisture shows up behind the wall covering

Humid corridors condense on ductwork and behind vinyl wall coverings. The result is a renovation line item on the property improvement plan.

Systems

Recommended systems

The KCC equipment that fits this building type, and the roof interface it lands on.

PRIMARY RECOMMENDATION

Viking OA

Supply dewpoint as low as 43°F held through modulating hot-gas reheat, corridor static-pressure reset on the VFD supply fan, and a total-energy wheel recovering the bathroom exhaust it is replacing. Powered exhaust with split return on OAK and OAN cabinets.
PAIRED SYSTEM

Viking HA

The mixed-air platform for lobbies, ballrooms, fitness and food-and-beverage spaces, where partial outdoor air and a moderate latent load call for the same cabinet and controls.
ROOF INTERFACE

Curbs & adapters

Curb adapters for replacement over existing openings on renovation cycles, structural curbs, gutters and walkways from one source. Rigging and corner weights in IOM-A001 ahead of a night lift.
Codes & Compliance

Codes & compliance

ASHRAE 62.1

Make-up for continuous bathroom exhaust delivered at a controlled dewpoint; dwelling-unit ventilation via corridor or ducted supply.

ASHRAE 90.1 / IECC

Total-energy wheel addresses exhaust air energy recovery provisions; engineered to exceed part-load (ISMRE2) benchmarks.

IMC / IBC

Corridor make-up air and positive pressurization maintained by fan reset against the exhaust riser.

AHRI 920 / 1060

Certified DX-DOAS performance; wheel effectiveness on the AHRI 1060 rating basis.

PROJECT PROOF
Named project, named outcome

One-line result with a number in it. Every vertical page carries at least one installed-performance proof point.

FAQ

Frequently asked questions

What is a hotel corridor makeup air unit?

A unit that replaces the air exhausted continuously from guest bathrooms by supplying conditioned outdoor air to the corridors, which pressurizes them and feeds the guestrooms. When that air is delivered dry and neutral, as Viking OA does at a supply dewpoint as low as 43°F, the guestroom terminal units carry sensible load only.
Because the make-up air for continuous bathroom exhaust is often tempered for temperature but not dehumidified. It arrives at outdoor dewpoint, condenses on cool surfaces and migrates behind wall coverings. Dewpoint-controlled make-up air removes the moisture at the unit before it reaches the corridor.
Yes. Corridor pressurization and dwelling-unit make-up air follow the same duty cycle in apartments, senior living and student housing. The unit is selected at the outdoor condition and the ventilation rate, not the building’s brand.
Yes, where the exhaust is ducted to the unit. The total-energy wheel transfers sensible and latent energy from the exhaust stream to the intake, with modulating bypass dampers so recovery is a controlled variable. Effectiveness is established on the AHRI 1060 rating basis.